Pharmaceutical water systems: a plain guide to WHO’s 2021 water GMP
Water is the most used raw material in a pharma plant and is not batch-tested before use. What WHO TRS 1033 Annex 3 expects of purified water and WFI systems.

In this article
Unlike other ingredients, water in a pharmaceutical plant is usually drawn on demand from a running system. It is not tested and released batch by batch before use. That is why regulators look so closely at water systems. The World Health Organization’s current guidance is Good manufacturing practices: water for pharmaceutical use, Annex 3 of Technical Report Series 1033, published in 2021. It replaced the 2011 version (TRS 970, Annex 2) and brought in WHO’s revised thinking on water for injections.
The grades of water
- Drinking water: the starting point, and acceptable for some early process steps.
- Purified water: for most non-sterile products and cleaning.
- Water for injections (WFI): for parenteral products and final rinses of sterile equipment.
What the guidance expects
- Design to keep water clean after treatment: storage and distribution should prevent re-contamination, with suitable materials, no dead legs and continuous circulation.
- Control microbes: sanitisation (often hot water or ozone) and bioburden control are a priority.
- Monitor continuously: conductivity, total organic carbon and temperature online, with microbial sampling at points of use.
- Qualify and review: water systems are qualified in phases and reviewed regularly, with trends looked at, not only single results.
- Allow other WFI methods: WFI no longer has to be made only by distillation, if an equivalent, validated method is used.
Buying a system
Ask suppliers for the design basis, materials and surface finish, sanitisation method, monitoring instruments, qualification documents and local service. Water treatment companies are among the exhibitors at Pharma Asia. For sterile plants, see also Annex 1, isolators and RABS.
How a typical system is built
A purified water system usually starts with pre-treatment of the incoming drinking water: filtration, softening and removal of chlorine. The water then passes through reverse osmosis, often followed by electrodeionisation, to reach the required purity. The purified water is stored in a tank and pumped continuously around a loop to the points of use, at a speed and temperature that limit the growth of microbes. Water for injections needs a further step, such as distillation or another validated method, and is usually kept hot.
Common problems inspectors find
- Dead legs and poorly sloped pipes, where water stands still and microbes grow.
- Sanitisation that is not done often enough, or not proven to work.
- Sampling plans that miss the points actually used in production.
- Alert and action limits that are never reviewed, or results that are not trended.
- Changes to the system made without change control or requalification.
Qualification in phases
WHO’s guidance expects a new system to be proven over time. In the first phase, the system is sampled intensively to show that it produces water of the right quality. In the second, sampling continues while the water is used, to show consistent performance. The third phase covers a longer period, usually a year, to show that the system copes with seasonal changes in the incoming water. After that, routine monitoring and periodic review keep it under control.
For plants planning new systems, read also HVAC for non-sterile plants.
Questions readers ask
Which WHO document applies?
Good manufacturing practices: water for pharmaceutical use, TRS 1033, Annex 3 (2021), which replaced TRS 970, Annex 2 (2011).
Must WFI be made by distillation?
No longer only by distillation. An equivalent, validated method may be used.
How often should water be tested?
Set sampling by risk, with points of use covered and results trended over time. Online conductivity, TOC and temperature are monitored continuously.
Meet the industry at Pharma Asia 2027
The 25th Pharma Asia International Exhibition & Conferences runs from 7 to 9 December 2027 at the Karachi Expo Centre. Read Pharma Asia 2027: dates, rates and how to book or send an enquiry through the Book a stand page.